New-Flow CVA_CVD

CVA_CVD – Konstantdurchflussventile

PDF-Download:CVA_CVD

The CVA series is used where the pressure at the inlet is variable and the pressure at the outlet is constant.
The CVD series is used where the pressure at the inlet is constant and the pressure at the outlet is variable.
Flow Rate: Liquid- max. 200 cc/min water, bigger than it on request
Gas- max. 30 NL/Min air, bigger than it on request
Process Connection: 1/4"NPT female, others on request
Temperature Limit: 120°C max.
Pressure Limit: 10 kg/cm 2 , bigger than it on request
Controllable Differential Pressure: Air- mini. 0.02 kg/cm 2 , max. 4 kg/cm 2 ;
Liquid- mini. 0.2 kg/cm 2 , max. 4 kg/cm 2 ;
Special range on request
Accuracy: +/-5% FS
Material: Body and Metal parts- SS316;
Membrane- Teflon, option on request